Stand Alone Combo Operated Eyewasher in South Africa
Stand Alone Combo Operated Eyewasher is a dedicated eye-irrigation station activated by either the foot pedal or hand control for fast, flexible operation, and ESEW Shower & Stainless Steel supplies this product across South Africa under part number SAEB10. The floor-mounted stand provides a permanent eye-flushing point without an overhead shower. The foot pedal or hand control starts the flow, allowing the user to hold both eyelids open above the paired spray heads.
ESEW manufactures fixed shower structures in 304 stainless steel, 316 stainless steel or mild steel where applicable. The correct material and configuration depend on chemical exposure, installation conditions, water supply and the site's risk assessment.

Request Pricing and Lead Times
Speak to ESEW about specifications, materials, delivery and installation for Stand Alone Combo Operated Eyewasher (SAEB10).
Key Takeaways
| Product feature | Site benefit |
|---|---|
| Rapid activation | Starts emergency flushing without delay |
| Stay-open or hands-free operation | Allows the user to remove contamination or hold eyelids open |
| Purpose-matched configuration | Supports the risks and physical layout at the installation point |
| Inspection and maintenance access | Helps the site keep the equipment ready for an emergency |


















How Stand Alone Combo Operated Eyewasher Works
Use the foot pedal or hand control to open the stay-open eyewash valve. This product forms part of an emergency eyewash and safety shower station system selected according to the identified workplace hazard. The user should begin flushing immediately and continue without interruption.
A plumbed eyewash should provide at least 1.5 litres per minute of controlled tepid water for 15 minutes. Clear access, visible signage and a reliable water or stored-fluid supply are essential to effective emergency use.
Activation and Response Sequence
Materials, Configuration and Product Selection
The floor-mounted stand provides a permanent eye-flushing point without an overhead shower. The foot pedal or hand control starts the flow, allowing the user to hold both eyelids open above the paired spray heads. ESEW reviews the intended location, chemical environment, expected user access and plumbing arrangement before confirming a configuration.
Grade 304 stainless steel suits many general industrial installations. Grade 316 stainless steel offers stronger resistance where chlorides, coastal air or aggressive chemicals are present. Mild steel can suit controlled environments when the protective finish and maintenance plan match the site conditions. Plastic components such as polypropylene bowls are selected for chemical resistance and ease of cleaning.
Compliance, Placement and Maintenance
ESEW aligns relevant equipment with ANSI/ISEA Z358.1-2014 principles and the emergency washing requirements discussed in OSHA guidance on emergency eyewash and shower facilities. Emergency equipment should be reachable within about 10 seconds on the same floor, with no locked doors, stored equipment or other obstructions in the route.
Facilities across Gauteng and South Africa install ESEW products in laboratories, dosing rooms, battery areas, workshops and chemical-handling stations. Plumbed equipment should be activated weekly and inspected on a planned schedule. Teams should verify controls, spray patterns, drainage, water quality, signage and access. All ESEW shower valves carry a six-month warranty.
Installation and Inspection Checklist
- Confirm the hazard type and required emergency response equipment.
- Position the unit within a clear 10-second travel path where applicable.
- Verify the water supply, drainage or fluid capacity required for the product.
- Keep operating controls visible and accessible.
- Test operation and record routine inspections.
- Quote part number SAEB10 when requesting support.
Frequently Asked Questions
What is the part number for this product?
The product part number is SAEB10. Include this code in pricing, delivery and technical-support enquiries.
How quickly should the equipment activate?
Emergency washing equipment should begin operating in one second or less where the standard applies. The valve or control should remain open without continuous hand pressure.
How close should emergency equipment be to the hazard?
The unit should normally be reachable within about 10 seconds along a clear route on the same floor. The site's risk assessment may require closer placement for highly corrosive substances.
How often should the equipment be checked?
Activate plumbed equipment weekly and complete documented inspections on the site's planned schedule. Portable products should be checked for expiry dates, seals, completeness and damage.
What warranty applies?
All ESEW shower valves carry a six-month warranty. Contact sales with the part number or product details for service and replacement support.
Visit ESEW Shower & Stainless Steel